4602-LV
Inductive Load Tester
Tesec has various types of Inductive Load tester that observes the shape of waveforms in the inductive load of MOSFET at the turn off and judges whether to pass within the Safety Operation Area (SOA) defined by V-Gate, IH and IL. In addition, the VDS value in the current value provided by IH can be measured.
Features |
|||||||||
♦Measure N/P channel at one test head |
|
||||||||
♦Measure Peak Current (IDP) at Avalanche |
|||||||||
♦Gate On Time can be measured |
|||||||||
♦Repeat test up to 250 times |
|||||||||
♦Multi test function(with fixed VD) |
|||||||||
♦Max. 60 test program can be stored |
|||||||||
♦VD-OFF mode |
|||||||||
♦SELF-CHECK FUNCTION |
|||||||||
♦Time-Trip mode |
|||||||||
|
|||||||||
Software Options |
|||||||||
♦Test control software by PC |
|||||||||
(Creating/Downloading of test programs, Data collections, counter) |
Model |
4602-LV |
4604-HB |
5604-HB* |
Applicable Devices |
MOSFET, Transistor, IGBT |
||
Drain Current (Id) |
0.5 - 200.0A |
|
|
Peak Drain Current (Idp) |
0.5 - 250.0A |
|
|
Drain Voltage (Vd) |
10.0 - 300.0V * |
|
|
Base Current (IB) |
- |
|
|
Reverse Base Current (Ibr) |
|
||
Gate Voltage (Vg) |
00.0 -30.0V |
|
|
Reverse Gate Voltage (Vgr) |
00.0 - 30.0V |
|
|
Clamp Voltage |
Unclamp |
|
|
Voltage Limit |
|
0000 - 2000V |
0000 - 5000V
|
(V-GATE) |
000.0 - 200.0V |
|
|
IH Limit |
000.5 - 200.0A |
|
|
IL Limit |
000.1 - 200.0A |
|
|
Gate On Time (TG) |
000.0us - 9.999ms |
|
|
Post-Short Detecting Time(DT) |
001us - 9.99ms |
|
|
|
|||
*VD-OFF MODE: 10.0V~200.0V 5604-HB* : Latest development and applicable to installed testers with conditions. |
|||
*For details specification of each product, please contact us.
|